{"id":104,"date":"2019-01-26T18:00:23","date_gmt":"2019-01-26T18:00:23","guid":{"rendered":"https:\/\/daviderice.wordpress.com\/?page_id=104"},"modified":"2026-01-08T06:36:04","modified_gmt":"2026-01-08T12:36:04","slug":"nec-code-verifications","status":"publish","type":"page","link":"https:\/\/www.calcware.com\/?page_id=104","title":{"rendered":"NEC Code Verifications"},"content":{"rendered":"\n<p class=\"has-black-color has-text-color\">The calculation power of AmpCalc eliminates the restrictions inherent with the fixed configurations in the NEC Code.&nbsp; However, the following tables demonstrate that AmpCalc computes ampacities very close to the Code values when the same system configurations and cable properties are utilized.<\/p>\n\n\n\n<p><strong>Underground System Ampacity Tables in Article 310:<\/strong><\/p>\n\n\n\n<p class=\"has-text-color\" style=\"color:#a37300\"><a href=\"ftp:\/\/david2@calcware.com\/calcware.com\/www\/wp-content\/uploads\/2019\/01\/nec-77-2.pdf\" data-type=\"link\" data-id=\"https:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-77-2.pdf\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Table <\/strong><\/a><a href=\"https:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-77-2.pdf\" data-type=\"link\" data-id=\"https:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-77-2.pdf\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>310.60(C)(77)<\/strong><\/a> &#8211;\u00a0 Three Single-Insulated Copper Conductors in Underground Electrical Ducts, (Three Conductors per Electrical Duct).<\/p>\n\n\n\n<p class=\"has-blue-color has-text-color\"><strong><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-78.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Table <\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-78.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">310.60(C<\/a><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-78.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">)<\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-78.pdf\" data-type=\"link\" data-id=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-78.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">(<\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-78.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">78<\/a><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-78.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">)&nbsp;<\/a><\/strong> &#8211;&nbsp; Three Single-Insulated Aluminum Conductors in Underground Electrical Ducts, (Three Conductors per Electrical Duct).<\/p>\n\n\n\n<p class=\"has-text-color\" style=\"color:#a36300\"><strong><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-79.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Table <\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-79.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">310.60<\/a><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-79.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">(<\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-79.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">C)<\/a><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-79.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">(79)<\/a><\/strong> &#8211; Three Insulated&nbsp;Copper&nbsp;Conductors Cabled Within an Overall Covering, (Three-Conductor Cable), in Underground Electrical Ducts, (One Cable per Electrical Duct).<\/p>\n\n\n\n<p class=\"has-blue-color has-text-color\"><strong><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-80.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Table 310.60(<\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-80.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">C<\/a><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-80.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">)(<\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-80.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">80<\/a><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-80.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">)<\/a><\/strong><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-80.pdf\" target=\"_blank\" rel=\"noreferrer noopener\"><\/a> &#8211; Three Insulated&nbsp;Aluminum Conductors Cabled Within an Overall Covering, (Three-Conductor Cable), in Underground Electrical Ducts, (One Cable per Electrical Duct).<\/p>\n\n\n\n<p class=\"has-text-color\" style=\"color:#a36300\"><strong><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-81.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Table 310.60<\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-81.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">(<\/a><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-81.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">C)(<\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-81.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">81<\/a><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-81.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">)<\/a><\/strong> &#8211; Single-Insulated&nbsp;Copper&nbsp;Conductors Directly Buried in Earth, (Spaced).<\/p>\n\n\n\n<p class=\"has-blue-color has-text-color\"><strong><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-82-1.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Table <\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-82-1.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">310.60(<\/a><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-82-1.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">C)(<\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-82-1.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">82<\/a><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-82-1.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">)<\/a><\/strong> &#8211; Single-Insulated&nbsp;Aluminum&nbsp;Conductors Directly Buried in Earth, (Spaced).<\/p>\n\n\n\n<p class=\"has-text-color\" style=\"color:#a36300\"><strong><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-83.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Table 310.60(<\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-83.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">C)(<\/a><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-83.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">83)<\/a><\/strong> &#8211; Three Insulated Copper Conductors Cabled Within an Overall Covering, (Three-Conductor Cable), Directly Buried in Earth.<\/p>\n\n\n\n<p class=\"has-blue-color has-text-color\"><strong><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-84.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Table 310.60(C)<\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-84.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">(84<\/a><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-84.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">)<\/a><\/strong> &#8211; Three Insulated Aluminum Conductors Cabled Within an Overall Covering, (Three-Conductor Cable), Directly Buried in Earth.<\/p>\n\n\n\n<p class=\"has-text-color\" style=\"color:#a36300\"><strong><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-85.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Table <\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-85.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">310.60<\/a><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-85.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">(<\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-85.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">C)<\/a><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-85.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">(<\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-85.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">85<\/a><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-85.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">)<\/a><\/strong><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-85.pdf\" target=\"_blank\" rel=\"noreferrer noopener\"><\/a> &#8211; Three Triplexed Single-Insulated Copper Conductors Directly Buried in Earth.<\/p>\n\n\n\n<p class=\"has-blue-color has-text-color\"><strong><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-86.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Table 310.60<\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-86.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">(<\/a><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-86.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">C)<\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-86.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">(86<\/a><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-86.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">)<\/a><\/strong><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-86.pdf\" target=\"_blank\" rel=\"noreferrer noopener\"><\/a> &#8211; Three Triplexed Single-Insulated Aluminum Conductors Directly Buried in Earth.<\/p>\n\n\n\n<p><strong>Underground System Ampacity Tables in Informational Annex B:<\/strong><\/p>\n\n\n\n<p class=\"has-black-color has-text-color\"><strong><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-b310_5.pdf\" target=\"_blank\" rel=\"noreferrer noopener\" aria-label=\" (opens in a new tab)\">Table B.310.15(B)(2)(5)<\/a><\/strong>  &#8211;  Single Insulated Copper or&nbsp; Aluminum Conductors, Rated 0 through 2000 Volts,&nbsp; in Nonmagnetic Underground Electrical Ducts, (One Conductor per Electrical Duct).<\/p>\n\n\n\n<p class=\"has-black-color has-text-color\"><strong><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-b310_6.pdf\" target=\"_blank\" rel=\"noreferrer noopener\" aria-label=\" (opens in a new tab)\">Table B.310.15(B)(2)(6)<\/a><\/strong>  &#8211;  Three Insulated Copper or&nbsp; Aluminum Conductors, Rated 0 through 2000 Volts, Cabled Within an Overall Covering, (Three-Conductor Cable),&nbsp; in Underground Electrical Ducts, (One Cable per Electrical Duct).<\/p>\n\n\n\n<p class=\"has-black-color has-text-color\"><strong><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-b310_7.pdf\" target=\"_blank\" rel=\"noreferrer noopener\" aria-label=\" (opens in a new tab)\">Table B.310.15(B)(2)(7)<\/a><\/strong>  &#8211;  Single Insulated Copper or&nbsp; Aluminum Conductors, Rated 0 through 2000 Volts,&nbsp; in Underground Electrical Ducts, (Three Conductor per Electrical Duct).<\/p>\n\n\n\n<p class=\"has-black-color has-text-color\"><strong><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-b310_8.pdf\" target=\"_blank\" rel=\"noreferrer noopener\" aria-label=\" (opens in a new tab)\">Table B.310.15(B)(2)(8)<\/a><\/strong><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-b310_8.pdf\" target=\"_blank\" rel=\"noreferrer noopener\" aria-label=\" (opens in a new tab)\"> <\/a> &#8211;   Three Insulated Copper or&nbsp; Aluminum Conductors, Rated 0 through 2000 Volts, Cabled Within an Overall Covering, (Three-Conductor Cable), Directly Buried in Earth.<\/p>\n\n\n\n<p class=\"has-black-color has-text-color\"><strong><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-b310_9.pdf\" target=\"_blank\" rel=\"noreferrer noopener\" aria-label=\" (opens in a new tab)\">Table B.310.15(B)(2)(9)<\/a><\/strong><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-b310_9.pdf\" target=\"_blank\" rel=\"noreferrer noopener\" aria-label=\" (opens in a new tab)\"> <\/a> &#8211;  Three Triplexed Single Insulated Copper or&nbsp; Aluminum Conductors, Rated 0 through 2000 Volts, Directly Buried in Earth.<\/p>\n\n\n\n<p class=\"has-black-color has-text-color\"><strong><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-b310_10.pdf\" target=\"_blank\" rel=\"noreferrer noopener\" aria-label=\" (opens in a new tab)\">Table B.310.15(B)(2)(10)<\/a><\/strong>  &#8211;  Three Single Insulated Copper or&nbsp; Aluminum Conductors, Rated 0 through 2000 Volts, Directly Buried in Earth.<\/p>\n\n\n\n<p class=\"has-black-color has-text-color\"><strong><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-inf_3.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Informational Note Figure B.310.15<\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-inf_3.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">(<\/a><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-inf_3.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">B<\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-inf_3.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">)<\/a><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-inf_3.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">(2)(3)<\/a><\/strong> &#8211; Single insulated copper conductors, rated 0 through 5000 volts,\u00a0 in underground electrical ducts, (three conductors per electrical duct), nine single-conductor cables per phase.<\/p>\n\n\n\n<p class=\"has-black-color has-text-color\"><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-inf_4.pdf\" target=\"_blank\" rel=\"noreferrer noopener\"><\/a><strong><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-inf_4.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Informational Note Figure B.<\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-inf_4.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">310.15<\/a><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-inf_4.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">(<\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-inf_4.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">B<\/a><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-inf_4.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">)(2)(4)<\/a><\/strong> &#8211; Single insulated copper conductors, rated 0 through 5000 volts,\u00a0 in non-magnetic underground electrical ducts, (one conductor per electrical duct), four single-conductor cables per phase.<\/p>\n\n\n\n<p class=\"has-black-color has-text-color\"><strong><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-inf_5.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Informational <\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-inf_5.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Note <\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-inf_5.pdf\" data-type=\"link\" data-id=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-inf_5.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Figure <\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-inf_5.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">B<\/a><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-inf_5.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">.<\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-inf_5.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">310.15<\/a><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-inf_5.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">(B<\/a><a href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2026\/01\/nec-inf_5.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">)<\/a><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-inf_5.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">(2)(5)<\/a><\/strong><a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.calcware.com\/wp-content\/uploads\/2019\/01\/nec-inf_5.pdf\" target=\"_blank\" rel=\"noreferrer noopener\"><\/a> &#8211; Single insulated copper conductors, rated 0 through 5000 volts,\u00a0 in non-magnetic underground electrical ducts, (one conductor per electrical duct), five single-conductor cables per phase.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The calculation power of AmpCalc eliminates the restrictions inherent with the fixed configurations in the NEC Code.&nbsp; However, the following tables demonstrate that AmpCalc computes ampacities very close to the Code values when the same system configurations and cable properties &hellip; <a href=\"https:\/\/www.calcware.com\/?page_id=104\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":3,"featured_media":0,"parent":53,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-104","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.calcware.com\/index.php?rest_route=\/wp\/v2\/pages\/104","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.calcware.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.calcware.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.calcware.com\/index.php?rest_route=\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.calcware.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=104"}],"version-history":[{"count":42,"href":"https:\/\/www.calcware.com\/index.php?rest_route=\/wp\/v2\/pages\/104\/revisions"}],"predecessor-version":[{"id":828,"href":"https:\/\/www.calcware.com\/index.php?rest_route=\/wp\/v2\/pages\/104\/revisions\/828"}],"up":[{"embeddable":true,"href":"https:\/\/www.calcware.com\/index.php?rest_route=\/wp\/v2\/pages\/53"}],"wp:attachment":[{"href":"https:\/\/www.calcware.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=104"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}